Model | PV35-5K | PV35-6K | PV35-7500 | PV35-10K | PV35-12.5K | PV35-15K | ||||
Default Battery System Voltage | 24V
DC |
48V
DC |
24V
DC |
48V
DC |
24V
DC |
48V
DC |
48V
DC |
48V
DC |
48V
DC |
|
INVERTER OUTPUT | Continuous output power | 5KVA/
4.0KW |
8KVA/
4.8KW |
7.5KVA/
6.0KW |
10KVA/
8.0KW |
12.5KVA/
10.0KW |
15KVA/
12.0KW |
|||
Surge rating (20ms) | 12.0KW | 15.0KW | 18.0KW | 24.0KW | 30.0KW | 36.0KW | ||||
Capable of starting
electric motor |
2HP | 3HP | 3HP | 4HP | 5HP | 6HP | ||||
Output waveform | Pure sine wave/ same as input (bypass mode) | |||||||||
Inverter efficiency (Peak) | >88% | |||||||||
Line mode efficiency | >95% | |||||||||
Power factor | 0.8 | |||||||||
Nominal output
voltage RMS |
220V/230V/240VAC(+/-10%Â RMS) | |||||||||
Output frequency | 50Hz/60Hz +/-0.3 Hz | |||||||||
Short circuit protection | Yes(1sec after fault) | |||||||||
Typical transfer time | 10ms(max) | |||||||||
ACÂ INPUT | Voltage | 230VAC | ||||||||
Selectable voltage range | 155~280VAC(For Personal Computers) | |||||||||
Frequency range | 50Hz/60Hz (Auto sensing) 40-80Hz | |||||||||
BATTERY | Minimum start voltage | 20.0VDC/21.0VDC for 24VDC mode (40.0VDC/42.0VDC for 48VDC mode) | ||||||||
Low battery alarm | 21.0VDC+/-0.3V for 24VDC mode (42.0VDC+/-0.6V for 48VDC mode) | |||||||||
Low battery cutoff | 20.0VDC+/-0.3V for 24VDC mode (40.0VDC+/-0.6V for 48VDC mode) | |||||||||
High voltage alarm | 32.0VDC+/-0.3V for24VDC mode (64.0VDC+/-0.6V for 48VDC mode) | |||||||||
High battery
voltage recover |
31.0VDC+/-0.3V for 24VDC mode (62.0VDC+/-0.6V for 48VDC mode) | |||||||||
Idle Consumption
Search Mode |
<25W when power saver on | |||||||||
AC CHARGER | Output Voltage | Depends on battery type | ||||||||
Charger AC Input
Breaker Rating |
30A | 30A | 30A | 40A | 50A | 63A | ||||
Max charge power rating | 1/3 Rating power | |||||||||
Overcharge Protection S.D. | 31.4VDC for 24VDC mode(62.8VDC for 48VDC mode) | |||||||||
Maximum Charge Current | 65A | 35A | 65A | 40A | 65A | 50A | 70A | 80A | 100A | |
BTS | Continuous Output Power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature | ||||||||
BYPASS
&Â PROTECTION |
Input Voltage Waveform | Sine wave (grid or generator) | ||||||||
Nominal voltage | 220V/230V/240VAC | |||||||||
Max input AC voltage | 300VAC for 230VAC HV mode | |||||||||
Nominal input frequency | 50Hz or 60Hz | |||||||||
Overload Protection
(SMPSÂ Load) |
Circuit breaker | |||||||||
Output Short
Circuit Protection |
Circuit breaker | |||||||||
Bypass Breaker Rating | 40A | 40A | 40A | 50A | 63A | 63A | ||||
Max Bypass Current | 40Amp | 80Amp | ||||||||
Rated voltage | 24VDC/48VDC | |||||||||
PV open circuit voltage | Operational max =145VDC temperature corrected VOC | |||||||||
SOLAR CHARGER | Maximum PV Charge Current | 60A | 60A(120A Optional) | |||||||
DC Voltage | 24V/48V atuo work | 48V | ||||||||
Maximum PV Array Power | 1600
W |
3200
W |
1600
W |
3200
W |
1600
W |
3200
W |
3200W(6400W for 120A Optional) | |||
MPPT Range @ Operating
Voltage(VDC) |
32-145VDC FOR 24V mode, 64-145V for 48V mode | 64-145VDC | ||||||||
Maximum PV Array Open
Circuit Voltage |
147VDC | 147VDC | ||||||||
Maximum Efficiency | >98% | |||||||||
Standby Power
Consumption |
<2W | |||||||||
MECHANICAL
SPECIFICATIONS |
Mounting | Wall mount | ||||||||
Dimensions (W*H*D) | 414*575*211mm | 414*645*211mm | ||||||||
Net Weight (Solar CHG) kg | 38+2.5 | 48+2.5 | 49+2.5 | 60+2.5 | 66+2.5 | 70+2.5 | ||||
Shipping Dimensions
(W*H*D) |
505*701*330mm | 505*771*330mm | ||||||||
Shipping Weight
(Solar CHG) kg |
40+2.5 | 50+2.5 | 51+2.5 | 62+2.5 | 68+2.5 | 72+2.5 | ||||
OTHER | Operation
Temperature Range |
0°C to 40°C | ||||||||
Storage Temperature | -15°C to 60°C | |||||||||
Audible Noise | 60dB MAX | |||||||||
Display | LED+LCD | |||||||||
Loading
(20GP/40GP/40HQ) |
140pcs/280pcs/320pcs |
Previous product
Back to products
MUST 5KVA/5KW 48V,Mppt 80Amp
KSh93,000.00
Next product
MUST 8KVA/8KW/48V MPPT 100Amp
KSh165,400.00
MUST 6KVA/6KW/48V MPPT 100Amp
KSh125,750.00
- Power range 5KVA-15KVA;
- 24V/48VDC input voltage;
- Powerful charge reate up tp 100Amp;
- Pure sine wave output;
- LED + LCD display;
- MPPT solar charge controller 40A 45A 60A;
- MPPT effeciency may 98%;
- RS232 with free CD;
- Battery priority function;
- High efficiency design & ” power saving mode” to conserve energy.
Category: Hybrid Inverters
Description
Reviews (0)
Be the first to review “MUST 6KVA/6KW/48V MPPT 100Amp” Cancel reply